Get in touch with Zeyu lntelligent Industrial Company
IPC/WHMA-A-620 Crimp Pull-Force Checker
Class 3 minimum tensile (pull-off) force by wire size.
IPC/WHMA-A-620 Class 3 Minimum Pull-Off Force
55 N
Class 3 also requires the crimp to hold ≥90% of the wire’s ultimate tensile strength. Verify with crimp-height measurement (±0.05 mm window) and pull-force testing; crimp-force monitoring rejects any cycle deviating >5% from the golden sample.
| AWG | mm² | Min Pull-Force (N) |
|---|---|---|
| 20 | 0.50 | 55 |
| 16 | 1.00 | 100 |
| 12 | 2.50 | 160 |
Values per IPC/WHMA-A-620 Table 4-1 (intermediate gauges interpolated for planning). Always confirm against the current standard revision for your class.
WHY WE WRITE THIS
About ZEUEE Engineering Insights
ZEUEE shares technical guides based on real automation project experience. Since 2005, we have designed and manufactured non-standard automation equipment for connector assembly, wire harness production, robotic lines, vision inspection, and smart factory upgrades.
Founded in 2005
20,000 m² production base
120+ specialists
150+ R&D patents